★About the parameter's adjustment range
 : A value larger than the upper-limit value is entered or the value set for the currently-selected
    parameter becomes larger than the upper-limit value because another parameter was changed.
 : A value smaller than the lower-limit value is entered or the value set for the currently-selected
   parameter becomes smaller than the lower-limit value because another parameter was changed.
If the above alarm code  or  blinks, change the parameter setting below the  value or
above the  value, respectively. When any of these alarm codes is blinking, no change can be
made to any parameter.
4.1.1 How to set basic parameters [Basic parameter]
Every basic parameters can be set in the same way.
  [Procedure for setting a basic parameter]
    
MON
              
▲  ▼
        
        
ENT
        
▲  ▼
        
ENT
Follow the procedure below to set a basic parameter.
     (Example of setting: Changing the maximum frequency from 80 to 60 Hz)
Key operated
MON
▲  ▼
ENT
▲  ▼
ENT
After this,
Press this key to switch to setting
monitor mode.
Press these keys to select the
parameter you want to change.
Press this key to display the
parameter setting.
Press these key to change the
parameter setting.
Press this key to save the change.
LED display






→ Press this key to
ENT
 display the same
parameter setting
The operation frequency is displayed. (Out of operation.)
(If the monitor display mode setting parameter
set at [Operation frequency])
Press the [MON] key to call up the first basic parameter
 (automatic acceleration/deceleration).
Select "" by pressing the △ or ▽ key.
Press the Enter key to display the changed maximum
frequency.
Change the maximum frequency to 60 Hz by pressing▽
key.
Press the Enter key to save the change. Then,  and the
set maximum frequency are displayed alternately.
→ Press this key to
MON
switch to status
.
monitor mode.
D-2
★ The inverter is shipped with
certain parameters factory-set
by default.
★ Use "Parameter list" to select the
parameters you want to change.
★ If you feel puzzled about what to
do next during this operation,
press the Monitor key to return to
the first step (
is displayed).

Operation
→ Press these keys
▲  ▼
to call up other
parameters.
is
