[16] Functions for lift (2/2)
Communi
Title
cation No
0340
Heavy load torque during fixed speed in reverse direction
0341
Automatic light-load high-speed operation frequency
[17] Commercial/inverter switching function
Communi
Title
Function
cation No
Output signal selection of
0354
commercial power/inverter
switching
Commercial power/inverter
0355
switching frequency
0356
Inverter side switching waiting time Model dependent∼10.00 [s]
Commercial power side
0357
switching waiting time
Commercial power switching
0358
frequency holding time
[18] PID control
Communi
Title
Function
cation No
0360
Signal selection of PID control 0: PID control disabled, 1: VI/II, 2: RR, 3: RX, 4: RX2
0361
Delay filter
0362
Proportional (P) gain
0363
Integral (I) gain
0364
PID deviation upper limit
0365
PID deviation lower limit
0366
Differential (D) gain
[19] Speed feedback/positioning control
Communi
Title
Function
cation No
0367
Number of PG input pulses
0368
Number of PG input phases
0369
PG disconnection detection
0370
Electronic gear
0371
Position loop gain
0372
Positioning completion range 1∼4000
0373
Frequency limit at position control 1∼8000 [Hz/s], 8001: disabled
※(Reference section): Refer to the inverter's individual manual.
Function
Adjustment range
0∼250 [%]
30.0∼ [Hz]
Adjustment range
0: OFF, 1: Automatic switching in case of trip
2: Commercial power switching frequency setting enabled
3: Both (1+2)
0∼ [Hz]
0.37∼10.00 [s]
0.1∼10.0 [s]
Adjustment range
0∼255
0.01∼100.0
0.01∼100.0
0∼50 [%]
0∼50 [%]
0.00∼2.55
Adjustment range
1∼9999
1: Single-phase input, 2: Two-phase input
0: Disabled, 1: Enabled
100 to 4000 pulses/rotation
0.0∼100.0
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
1
100
Enabled
●/●
0.01/0.01
80.0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Disabled
−
●/●
0.01/0.01
60.0
Enabled
●/●
0.01/0.01
See J-28
Enabled
●/●
0.01/0.01
0.62
Enabled
●/●
0.1/0.01
2.0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
−
0
Enabled
●/●
0
Enabled
−
●/●
0.01/0.01
0.1
Enabled
●/●
0.01/0.01
0.1
Enabled
●/●
1/0.01
50
Enabled
●/●
1/0.01
50
Enabled
●/●
0.01/0.01
0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
1/1
500
Disabled
−/●
−
2
Disabled
−/●
0
Disabled
−
−/●
1/1
1000
Disabled
−
0.1/0.01
4.0
Enabled
−
1/1
100
Enabled
−
1/1
800
Disabled
−
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
−
−
●
※
−
−
●
※
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.16
●/●
−
●
●/●
−
●
6.16
6.16
●/●
−
●
6.16
●/●
−
●
●/●
−
●
6.16
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
−
−
●
3.3
3.3
−
−
●
−
−
●
3.3
3.3
−
−
●
−
−
●
3.3
3.3
−
−
●
−
−
●
3.3
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
−/●
−/●
−
※
−/●
−/●
−
※
−/●
−/●
−
※
−
−/●
−
※
−
−/●
−
※
−
−/●
−
※
−
−/●
−
※