Toshiba TOSVERT VF-P7 Instruction Manual page 212

Inverter for fan and pump applications
Hide thumbs Also See for TOSVERT VF-P7:
Table of Contents

Advertisement

[16] Functions for lift (2/2)
Communi
Title
cation No
0340
Heavy load torque during fixed speed in reverse direction

0341
Automatic light-load high-speed operation frequency

[17] Commercial/inverter switching function
Communi
Title
Function
cation No
Output signal selection of
0354
commercial power/inverter

switching
Commercial power/inverter

0355
switching frequency
0356
Inverter side switching waiting time Model dependent∼10.00 [s]

Commercial power side
0357

switching waiting time
Commercial power switching

0358
frequency holding time
[18] PID control
Communi
Title
Function
cation No

0360
Signal selection of PID control 0: PID control disabled, 1: VI/II, 2: RR, 3: RX, 4: RX2
0361
Delay filter


0362
Proportional (P) gain
0363
Integral (I) gain


0364
PID deviation upper limit
0365
PID deviation lower limit


0366
Differential (D) gain
[19] Speed feedback/positioning control
Communi
Title
Function
cation No
0367
Number of PG input pulses


0368
Number of PG input phases
0369
PG disconnection detection


0370
Electronic gear
0371
Position loop gain


0372
Positioning completion range 1∼4000
0373
Frequency limit at position control 1∼8000 [Hz/s], 8001: disabled

※(Reference section): Refer to the inverter's individual manual.
Function
Adjustment range
0∼250 [%]
30.0∼ [Hz]
Adjustment range
0: OFF, 1: Automatic switching in case of trip
2: Commercial power switching frequency setting enabled
3: Both (1+2)
0∼ [Hz]
0.37∼10.00 [s]
0.1∼10.0 [s]
Adjustment range
0∼255
0.01∼100.0
0.01∼100.0
0∼50 [%]
0∼50 [%]
0.00∼2.55
Adjustment range
1∼9999
1: Single-phase input, 2: Two-phase input
0: Disabled, 1: Enabled
100 to 4000 pulses/rotation
0.0∼100.0
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
1
100
Enabled
●/●
0.01/0.01
80.0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Disabled
●/●
0.01/0.01
60.0
Enabled
●/●
0.01/0.01
See J-28
Enabled
●/●
0.01/0.01
0.62
Enabled
●/●
0.1/0.01
2.0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Enabled
●/●
0
Enabled
●/●
0.01/0.01
0.1
Enabled
●/●
0.01/0.01
0.1
Enabled
●/●
1/0.01
50
Enabled
●/●
1/0.01
50
Enabled
●/●
0.01/0.01
0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
1/1
500
Disabled
−/●
2
Disabled
−/●
0
Disabled
−/●
1/1
1000
Disabled
0.1/0.01
4.0
Enabled
1/1
100
Enabled
1/1
800
Disabled
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.16
●/●
●/●
6.16
6.16
●/●
6.16
●/●
●/●
6.16
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
3.3
3.3
3.3
3.3
3.3
3.3
3.3
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
−/●
−/●
−/●
−/●
−/●
−/●
−/●
−/●
−/●
−/●