[3] Terminal function selection (2/2)
Communi
Title
Function
cation No

0121
Input terminal selection #11
0122
Input terminal selection #12


0123
Input terminal selection #13
0124
Input terminal selection #14


0125
Input terminal selection #15
0126
Input terminal selection #16

0130
Output terminal selection #1 (OUT1) 0∼119


0131
Output terminal selection #2 (OUT2) 0∼119
0132
Output terminal selection #3 (FL)


0133
Output terminal selection #4
0134
Output terminal selection #5


0135
Output terminal selection #6
0136
Output terminal selection #7

[4] Terminal response time setup
Communi
Title
Function
cation No
0140
Input terminal #1 response time(F)


0141
Input terminal #2 response time(R)
0142
Input terminal #3 response time(ST)


0143
Input terminal #4 response time(RES)
0144
Input terminal #5-#8 response time


0145
Input terminal #9-#16 response time
0150
Output terminal #1 delay time (OUT1)


0151
Output terminal #2 delay time (OUT2)
0152
Output terminal #3 delay time (FL)


0153
Output terminal #4 delay time
0154
Output terminal #5 delay time


0155
Output terminal #6 delay time
0156
Output terminal #7 delay time


0160
Output terminal #1 holding time (OUT1)
0161
Output terminal #2 holding time (OUT2)

0162
Output terminal #3 holding time (FL)


0163
Output terminal #4 holding time
0164
Output terminal #5 holding time


0165
Output terminal #6 holding time
0166
Output terminal #7 holding time

(*1)The minimum setting unit is 2.5 [ms]. Please input a value which is a multiple of 2.5 and ommitted below the decimal point.
Adjustment range
0∼135
0∼135
0∼135
0∼135
0∼135
0∼135
0∼119
0∼119
0∼119
0∼119
0∼119
Adjustment range
2 to 200 [ms] (in steps of 2.5 [ms])
2 to 200 [ms] (in steps of 2.5 [ms])
2 to 200 [ms] (in steps of 2.5 [ms])
2 to 200 [ms] (in steps of 2.5 [ms])
2 to 200 [ms] (in steps of 2.5 [ms])
2 to 200 [ms] (in steps of 2.5 [ms])
2 to 200 [ms] (in steps of 2.5 [ms])
2 to 200 [ms] (in steps of 2.5 [ms])
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
4(LOW) Disabled
●/●
6(RCH) Disabled
●/●
10(FL)
Disabled
●/●
0
Disabled
●/●
2
Disabled
●/●
8
Disabled
●/●
14
Disabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
(*1)
8
Disabled
●/●
(*1)
8
Disabled
●/●
(*1)
8
Disabled
●/●
(*1)
8
Disabled
●/●
(*1)
8
Disabled
●/●
(*1)
8
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
(*1)
2
Disabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
7.2.1
7.2.1
●/●
−/●
●/●
−/●
7.2.1
7.2.1
●/●
−/●
●/●
−/●
7.2.1
7.2.1
●/●
−/●
7.2.2
●/●
−/●
●/●
−/●
7.2.2
7.2.2
●/●
−/●
●/●
−/●
7.2.2
7.2.2
●/●
−/●
●/●
−/●
7.2.2
7.2.2
●/●
−/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●
●/●
−/●
7.2.3
7.2.3
●/●
−/●