Toshiba TOSVERT VF-P7 Instruction Manual page 205

Inverter for fan and pump applications
Hide thumbs Also See for TOSVERT VF-P7:
Table of Contents

Advertisement

2. Extended parameters
[1] Frequency signal
Communi
Title
Function
cation No.

0100
Low-speed signal output frequency 0.0∼ [Hz]
0101
Speed reach setting frequency


0102
Speed reach detection band 0.0∼ [Hz]
[2] Input signal selection
Communi
Title
Function
cation No.

0103
ST (standby) signal selection 0: Standard, 1: Always ON, 2: Interlock with F/R terminal
0105
Priority selection (both F-CC, R-CC are ON) 0: Reverse, 1: Stop


0106
Priority setting of input terminal
Binary/BCD signal selection

0107
(Expansion TB option unit)
0108
Up-down frequency

[3] Terminal function selection (1/2)
Communi
Title
Function
cation No.

0110
Always active function selection 0∼135
0111
Input terminal selection #1 (F)


0112
Input terminal selection #2 (R)

0113
Input terminal selection #3 (ST)
0114
Input terminal selection #4 (RES) 0∼135


0115
Input terminal selection #5 (S1)
0116
Input terminal selection #6 (S2)


0117
Input terminal selection #7 (S3)
0118
Input terminal selection #8 (S4)


0119
Input terminal selection #9
0120
Input terminal selection #10

※(Reference section): Refer to the inverter's individual manual.
Adjustment range
0.0∼ [Hz]
Adjustment range
0: Disabled, 1: Enabled
0: None
1: 12-bit binary input
2: 16-bit binary input
3: 3-digit BCD input
4: 4-digit BCD input
5: Reverse 12-bit binary input
6: Reverse 16-bit binary input
7: Reverse 3-digit BCD input
8: Reverse 4-digit BCD input
0∼7
Adjustment range
0∼135
0∼135
0∼135
0∼135
0∼135
0∼135
0∼135
0∼135
0∼135
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
2.5
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
1/1
0
Disabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Disabled
●/●
2(F)
Disabled
●/●
4(R)
Disabled
●/●
6(ST)
Disabled
●/●
8(RES)
Disabled
●/●
10(S1)
Disabled
●/●
12(S2)
Disabled
●/●
14(S3)
Disabled
●/●
16(S4)
Disabled
●/●
0
Disabled
●/●
0
Disabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
6.1.1
6.1.2
●/●
−/●
●/●
−/●
6.1.2
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
6.2.1
6.2.2
●/●
−/●
●/●
−/●
6.2.3
●/●
−/−
−/−
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
6.3.1
7.2.1
●/●
−/●
●/●
−/●
7.2.1
●/●
−/●
7.2.1
7.2.1
●/●
−/●
●/●
−/●
7.2.1
7.2.1
●/●
−/●
●/●
−/●
7.2.1
7.2.1
●/●
−/●
●/●
−/●
7.2.1
7.2.1
●/●
−/●