6.22 Torque limit
:Selection of power running torque limit #1
:Power running torque limit #1
:Selection of regenerative torque limit #1
:Regenerative torque limit #1
:Power running torque limit #2
:Regenerative torque limit #2
:Power running torque limit #3
:Regenerative torque limit #3
:Power running torque limit #4
:Regenerative torque limit #4
:Torque limit mode (polarity)
・
Function
The function is to decrease or increase the output frequency according to the load
ing condition when the motor torque reaches the limit level.
Setting a torque limit parameter at 250.0 means "Invalid".
■Setting
(1) Power running /regenerative torque limit
First, you need to set the polarity of each torque limit. Set at .
Title
a)limiting the torque with internal parameters (or on communication mode)
Reverse
Torque limits can be set with the parameters and .
[Setting of power running torque]
(Selection of power running torque limit #1) :Set at ( )
(Power running torque limit #1)
[Setting of regenerative torque]
(Selection of regenerative torque limit #1)
(Regenerative torque limit #1)
RR-CC ―― 0∼10V
RX-CC ―― 0∼±10V
VI-CC
II-CC
Function
Torque limit
mode (polarity)
Regenerative
Power running
(0∼250%)
(0∼250%)
―― 0∼10V
(0∼250%)
―― 4(0)∼20mA (0∼250%)
Adjustment range
: Power running/regenerative torque limit
: Positive/negative torque limit
Power running
Regenerative
:Set a desirable torque limit level.
:Set at ( )
:Set a desirable torque limit level.
F-44
,
Setting value
+250% torque
Forward
−
250% torque