Code
Main Cause/Detail of Detection
***: Finisher-Z1 ****: Finisher-Y1, Saddle Finisher-Y2 *****: Puncher Unit
8001 Open of the inlet cover is detected for 1 sec. or more after the host machine
starts initial rotation/printing while the following sensors detect their covers
closed.
- Inlet cover sensor (PI9S)
- Front cover open/close sensor (PI2S)
- Delivery cover sensor (PI3S)
Or, the front cover switch (MS2S) or the delivery cover switch (MS3S) is
open.
8002 Open of the front cover switch is detected for 1 sec. or more after the host
machine starts initial rotation/printing while the following sensors detect their
covers closed.
- Inlet cover sensor (PI9S)
- Front cover open/close sensor (PI2S)
- Delivery cover sensor (PI3S)
8003 Open of the delivery cover switch is detected for 1 sec. or more after the host
machine starts initial rotation/printing while the following sensors detect their
covers closed.
- Inlet cover sensor (PI9S)
- Front cover open/close sensor (PI2S)
- Delivery cover sensor (PI3S)
- Delivery cover switch (MS3S)
E601
Abnormality of image memory
0000 Communication error of the image memory (SDRAM)
E602
Hard disk error
E604
The image memory (SDRAM) is faulty/insufficient
0000 Memory capacity required for a model fails to be recognized.
0001 Memory for MEAP application is insufficient.
0002 The image memory of larger than 1.5GB is installed (at activation)
0512 Memory is faulty/insufficient (512MB is required)
0768 Memory is faulty/insufficient (768MB is required)
1024 Memory is faulty/insufficient (1024MB is required)
1536 Memory is faulty/insufficient (1536MB is required)
E609
Abnormal low temperature of the hard disk
0008 At start-up, temperature of the HDD fails to reach the specific level within a
specific period of time.
0009 During recovery from sleep mode, temperature of the HDD is below the
specific level within the specific period of time.
E610
Failure in the hard disk cryptographic key
0001 The encryption board is not attached.
0002 Memory is faulty/insufficient
0101 Initialization of a key storage area in the memory ends in failure.
0102 Initialization of code processing ends in failure.
0201 Code processing error
0202 Code processing error
0301 Creation of a cryptographic key ends in failure.
0302 Failure in the cryptographic key is detected.
0303 Failure in the cryptographic key is detected.
0401 Error is detected during encrypting.
0402 Error is detected during decoding.
E611
Error in repeat of reboot due to fault of SRAM, etc.
0000 SRAM information is broken, job information stored in SRAM cannot be read
and reboot is repeated at recovery from power-off
E674
FAX board communication error
0001 Communication error between the FAX board and the main controller PCB is
detected for the specific number of times.
0004 Access to the modem IC is abnormal.
0008 Access to the port IC is abnormal.
000C Access to the modem IC and port IC is abnormal.
0010 Abnormality is detected when the timer device is open.
0011 Abnormality is detected when the timer device starts.
E677
Abnormality of the external controller
0003 Abnormality of the external controller
Abnormality is detected in configuration check when the external controller
starts up.
0010 Controller for other mode is connected.
0080 Communication with the printer is abnormal after the external controller starts
up properly.
E710
IPC initialization error
0000 Error in initialization of IPC chip
16-8
Countermeasures
Replace the inlet cover switch (MS1S), Replace the front cover
switch (MS2S), Replace the delivery cover switch (MS3S)
Replace the front cover switch (MS2S), Replace the delivery
cover switch (MS3S)
Replace the inlet cover switch (MS1S), Replace the front cover
switch (MS2S), Replace the delivery cover switch (MS3S)
Replace the SDRAM
Refer to [Details of E602]
Add on the SDRAM
Make the memory 1.5GB or less.
Add on the SDRAM
Replace the HDD
Attach the encryption board
Add on memory
Turn OFF and back ON the main power, Replace the main
controller PCB
Turn OFF and back ON the main power, Replace the encryption
board
Turn OFF and back ON the main power, Replace the main
controller PCB
The HDD will be initialized due to the error.
Turn OFF and back ON the main power, Replace the encryption
board
Clear SRAM to delete the shutdown assurance job.
Check on connection between the FAX board and the main
controller PCB, Replace the FAX board, Replace the main
controller PCB
Replace the main controller PCB
Check on connection of the cable, Re-install the external
controller system
Connect an appropriate controller, Re-install the external
controller system
Check on connection of the cable, Re-install the external
controller system
Check the connection of cable, Replace the DC controller PCB