iR C3380i / iR C3380 / iR C2880i / iR C2880 / iR C3580 / iR C3580i / iR C3080 / iR C3080i / iR C2380i
The machine is equipped with a breaker for detection of over-current and leakage current for enhanced safety, and it is important to check and see that the breaker
operates properly.
Advise the user to check the breaker on a periodical basis (about once a month), and keep a record of inspection.
Go through the following:
1) Turn off the main power switch.
2) Push the test button [1] of the breaker with the tip of a ball-point pen or the like.
3) Check to see that the breaker switch [1] shifts to the OFF side.
4) Shift the breaker switch [1] back to the ON side.
Check to be sure that the breaker switch is on the ON side. If it has stopped between the ON and OFF sides, push it back to the OFF side and then to the ON side.