Download Print this page

Toshiba 610CT Maintenance Manual page 110

Hide thumbs Also See for 610CT:

Advertisement

Assembly Procedures
After you have disassembled the 610CT and fixed or repaired the problem that was causing
the 610CT to operate abnormally, you will need to reassemble the 610CT.
While assembling the 610CT, remember the following general points:
Take your time, making sure you follow the instructions closely. Most problems arise
when you hurry to assemble the 610CT.
Make sure all cables and connectors are securely fastened.
Before securing the FRU or other parts, make sure that no cables will be pinched by
screws or the FRU.
Check that all latches are closed securely in place.
Make sure all the correct screws are used to secure all FRUs. Using the wrong screw
can damage the screw and may prevent proper seating of an FRU.
After installing an FRU in the 610CT, confirm that the FRU and the 610CT are functioning
properly.
Tools and Equipment
The use of ElectroStatic Discharge (ESD) equipment is very important for your safety and the
safety of those around you. Proper use of these devices will increase the success rate of your
repairs and lower the cost for damaged or destroyed parts. The following equipment is
necessary to disassemble and reassemble the 610CT:
One M2 Phillips screwdriver to remove and replace screws.
Tweezers, to lift out screws that you cannot grasp with your fingers.
ESD mats for the floor and the table you are working on.
An ESD wrist strap or heel grounder.
Anti-static carpeting or flooring.
Air ionizers in highly static sensitive areas.