Secondary Swing Flap Motor - Daikin Emura RXJ20A5V1B Service Manual

Split 3 r32
Hide thumbs Also See for Emura RXJ20A5V1B:
Table of Contents

Advertisement

4
|
Components
To remove the swing flap motor wiring harness
To install the swing flap motor wiring harness

4.17.2 Secondary swing flap motor

Checking procedures
To perform an electrical check of the swing flap motor
Service manual
164
3 Install the main swing flap in the indoor unit (by clicking it on).
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the main swing flap motor gearcase assembly, see
4
procedures" [
 163].
INFORMATION
The swing flap motor wiring harness is ALSO connected to the secondary swing flap
motor and swing raster motor.
2 Remove the secondary swing flap motor gearcase assembly, see
4
procedures" [
 166].
3 Cut all tie straps that fix the swing flap motor wiring harness.
4 Route the swing flap motor wiring harness out of the harness retainers.
5 Remove the swing flap motor wiring harness.
6 To
install
the
4
procedures" [
 163].
1 Route the swing flap motor wiring harness through the appropriate retainers.
2 Install the main swing flap motor gearcase assembly, see
procedures" [
4
 163]. Do NOT yet install the main swing flap on the indoor unit.
3 Install the secondary swing flap motor gearcase assembly, see
4
procedures" [
 166].
4 Install new tie straps to fix the swing flap motor wiring harness.
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Disconnect the swing flap motor connector from the indoor unit main PCB.
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
swing
flap
motor
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
4
"4.14 Plate
work" [
 144].
wiring
harness,
see
4
"4.14 Plate
work" [
 144].
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08
"Repair
"Repair
"Repair
"Repair
"Repair

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents