Repair Procedures - Daikin Emura RXJ20A5V1B Service Manual

Split 3 r32
Hide thumbs Also See for Emura RXJ20A5V1B:
Table of Contents

Advertisement

4
|
Components

4.8.2 Repair procedures

To remove the DC fan motor assembly
To install the DC fan motor assembly
Service manual
102
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Click the indoor unit fan motor cover out of the indoor unit. If needed, remove
the screw (if installed) on the right hand side of the fan motor cover for easier
removal.
a Indoor unit fan motor cover
3 Remove the rubber from the indoor unit.
4 Remove the indoor unit fan motor from the indoor unit.
5 To install the indoor unit fan motor, see
1 Install the indoor unit fan motor in its correct location on the fan.
2 Install the rubber in front of the fan motor.
3 Click the indoor unit fan motor cover on the indoor unit. If removed, install
and tighten the screw on the right hand side of the fan motor cover.
"4.14 Plate
4
"4.14 Plate
work" [
a
"4.8.2 Repair
4
work" [
 144].
 144].
4
procedures" [
 102].
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents