“Silent” buttons on the remote control lower the operation sound of the outdoor unit by 3dBA. • Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. •...
• Outdoor Units • R-410A • RX-JV/GV Electrical data RX20-35JV Representative unit combination Power supply Comp Indoor unit Outdoor unit Hz-Volts Voltage range 50 - 220 Max. 50Hz 264V FTX20JV1B RX20JV1B 50 - 230 14.5 0.17 0.12 Min. 50Hz 198V...
• Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing RX20-35JV MINIMUM SPACE FOR AIR PASSAGE Wall height on air outlet side = less than 1200 Drain outlet ( I, D ø 15.9 hose for connection...
Page 17
• Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing • Split Sky Air • Outdoor Units...
• Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RX20-25JV 4D058111C RX35JV 4D058147C • Split Sky Air • Outdoor Units...
Page 19
• Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RX50-60GV The position of foundation bolt 4D051638P RX71GV Position of anchor bolt 4D053630D • Split Sky Air • Outdoor Units...
Page 23
• Outdoor Units • R-410A • RX-JV/GV Wiring diagram 7 - 1 Wiring diagram RX50G Power supply To indoor unit Sheet metal indoor Field wiring LED A (outdoor) (discharge) (condenser) Outdoor Z1C~Z5C Ferrite core LEDA Pilot lamp X1M, X2M Terminal strip...
Page 24
• Outdoor Units • R-410A • RX-JV/GV Wiring diagram 7 - 1 Wiring diagram RX60G Power supply To indoor unit Sheet metal indoor Field wiring LED A (outdoor) (discharge) (condenser) Outdoor Z1C~Z4C Ferrite core LEDA Pilot lamp X1M, X2M Terminal strip...
Page 25
• Outdoor Units • R-410A • RX-JV/GV Wiring diagram 7 - 1 Wiring diagram RX71GV Power supply To indoor unit Sheet metal indoor Field wiring LED A (outdoor) (discharge) (condenser) Outdoor Z1C~Z7C Ferrite core LEDA Pilot lamp X1M, X2M Terminal strip...
• Outdoor Units • R-410A • RX-JV/GV Sound data 8 - 1 Sound pressure spectrum RX20JV Cooling Heating Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz)
Page 27
• Outdoor Units • R-410A • RX-JV/GV Sound data 8 - 1 Sound pressure spectrum RX35JV Cooling Heating Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz)
Page 28
• Outdoor Units • R-410A • RX-JV/GV Sound data 8 - 1 Sound pressure spectrum RX60G Cooling Heating Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz)
• Outdoor Units • R-410A • RX-JV/GV Operation range RX20-35JV Cooling (-15°C DB) Indoor temp. (°C WB) Indoor temp. (°C DB) 3D058975A The graphs are based on the following conditions. Equivalent piping length Level difference RX50-60G RX71GV Heating Cooling (-15°C DB) Indoor temp.
Page 30
The present publication is drawn up by way of information only and does not constitute an offer binding conditioning equipment, compressors and refrigerants upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its has led to its close involvement in environmental issues.