Technical Data

W a l l M o u n t e d U n i t
w w w . d a i k i n . e u
RX-JV/GV

Advertisement

Table of Contents
loading

Summary of Contents for Daikin RX-JV

  • Page 1: Technical Data

    Air Conditioners Technical Data W a l l M o u n t e d U n i t w w w . d a i k i n . e u RX-JV/GV...
  • Page 2 Air Conditioners Technical Data W a l l M o u n t e d U n i t w w w . d a i k i n . e u RX-JV/GV...
  • Page 3: Table Of Contents

    • Outdoor Units • R-410A • RX-JV/GV TABLE OF CONTENTS RX-JV/GV Features ............. 2 Specifications .
  • Page 4: Features

    “Silent” buttons on the remote control lower the operation sound of the outdoor unit by 3dBA. • Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. •...
  • Page 5: Specifications

    • Outdoor Units • R-410A • RX-JV/GV Specifications 2-1 Nominal Capacity and Nominal Input RX20JV1B RX25JV1B RX35JV1B For combination Indoor Units FTX20JV1B FTX25JV1B FTX35JV1B indoor units + outdoor units Cooling capacity Minimum Btu/h 4,400 Kcal/h 1,120 Standard Btu/h 6,800 8,500...
  • Page 6: Technical Specifications

    • Outdoor Units • R-410A • RX-JV/GV Specifications 2-1 Nominal Capacity and Nominal Input RX50G2V1B RX60G2V1B RX71GV1B Power Input Cooling Max. 2.08 2.40 3.20 Min. 0.44 0.57 Nom. 1.55 1.99 2.35 Heating Max. 2.53 2.81 3.82 Min. 0.40 0.52 Nom.
  • Page 7 • Outdoor Units • R-410A • RX-JV/GV Specifications 2-2 Technical Specifications RX20JV1B RX25JV1B RX35JV1B Refrigerant Oil Type FVC50K Charged Volume 0.375 0.375 0.375 Piping connections Liquid (OD) Quantity Diameter (OD) 6.35 6.35 6.35 Quantity Diameter (OD) 9.52 9.52 9.52 Drain...
  • Page 8: Electrical Specifications

    • Outdoor Units • R-410A • RX-JV/GV Specifications 2-2 Technical Specifications RX50G2V1B RX60G2V1B RX71GV1B Compressor Motor Model 2YC36BXD#C 2YC63BXD#A Type Hermetically sealed swing compressor Motor Output 1,20 1,10 1,92 Operation Range Cooling °CDB °CDB Heating °CWB °CWB Sound Level Cooling...
  • Page 9: Electrical Data

    • Outdoor Units • R-410A • RX-JV/GV Electrical data RX20-35JV Representative unit combination Power supply Comp Indoor unit Outdoor unit Hz-Volts Voltage range 50 - 220 Max. 50Hz 264V FTX20JV1B RX20JV1B 50 - 230 14.5 0.17 0.12 Min. 50Hz 198V...
  • Page 10: Capacity Tables

    • Outdoor Units • R-410A • RX-JV/GV Capacity tables 4 - 1 Cooling/Heating capacity tables • Split Sky Air • Outdoor Units...
  • Page 11 • Outdoor Units • R-410A • RX-JV/GV Capacity tables 4 - 1 Cooling/Heating capacity tables • Split Sky Air • Outdoor Units...
  • Page 12 • Outdoor Units • R-410A • RX-JV/GV Capacity tables 4 - 1 Cooling/Heating capacity tables • Split Sky Air • Outdoor Units...
  • Page 13 • Outdoor Units • R-410A • RX-JV/GV Capacity tables 4 - 1 Cooling/Heating capacity tables FTX50GV1B+RX50G2V1B 14.7 Cooling 50Hz 220-240V 0.28 Indoor Outdoor temperature (°C DB) °C °C 14.0 5.12 3.61 1.19 4.89 3.49 1.30 4.66 3.37 1.42 4.56 3.32 1.46...
  • Page 14 • Outdoor Units • R-410A • RX-JV/GV Capacity tables 4 - 1 Cooling/Heating capacity tables FTX60GV1B+RX60G2V1B 16.2 Cooling 50Hz 220-240V 0.29 Indoor Outdoor temperature (°C DB) °C °C 14.0 5.60 3.94 1.49 5.60 3.94 1.66 5.59 3.94 1.82 5.48 3.88 1.88...
  • Page 15 • Outdoor Units • R-410A • RX-JV/GV Capacity tables 4 - 1 Cooling/Heating capacity tables FTX71GV1B+RX71GV1B 17.4 50Hz 220-240V Cooling 0.30 Indoor Outdoor temperature (°C DB) °C °C 14.0 5.93 4.18 1.64 5.93 4.18 1.86 5.93 4.18 2.07 5.93 4.18 2.16...
  • Page 16: Dimensional Drawing & Centre Of Gravity

    • Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing RX20-35JV MINIMUM SPACE FOR AIR PASSAGE Wall height on air outlet side = less than 1200 Drain outlet ( I, D ø 15.9 hose for connection...
  • Page 17 • Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing • Split Sky Air • Outdoor Units...
  • Page 18: Centre Of Gravity

    • Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RX20-25JV 4D058111C RX35JV 4D058147C • Split Sky Air • Outdoor Units...
  • Page 19 • Outdoor Units • R-410A • RX-JV/GV Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RX50-60GV The position of foundation bolt 4D051638P RX71GV Position of anchor bolt 4D053630D • Split Sky Air • Outdoor Units...
  • Page 20: Piping Diagram

    • Outdoor Units • R-410A • RX-JV/GV Piping diagram RX20-25JV OUTDOOR UNIT Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor ON: Heating Discharge pipe thermistor Compressor Heating 3D058716B RX35JV OUTDOOR UNIT Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Four way...
  • Page 21 • Outdoor Units • R-410A • RX-JV/GV Piping diagram RX50-60G Outdoor unit 7.9CuT Heat exchanger Outdoor air temperature thermistor 7.9CuT 7.9CuT 7.9CuT Capillary tube 1 12.7CuT 7.9CuT 7.9CuT 4.0CuT Muffler 7.9CuT with 7.9CuT 4.0CuT Refrigerant flow 7.9CuT filter 6.4CuT Capillary tube 2 7.9CuT...
  • Page 22: Wiring Diagram

    • Outdoor Units • R-410A • RX-JV/GV Wiring diagram 7 - 1 Wiring diagram • Split Sky Air • Outdoor Units...
  • Page 23 • Outdoor Units • R-410A • RX-JV/GV Wiring diagram 7 - 1 Wiring diagram RX50G Power supply To indoor unit Sheet metal indoor Field wiring LED A (outdoor) (discharge) (condenser) Outdoor Z1C~Z5C Ferrite core LEDA Pilot lamp X1M, X2M Terminal strip...
  • Page 24 • Outdoor Units • R-410A • RX-JV/GV Wiring diagram 7 - 1 Wiring diagram RX60G Power supply To indoor unit Sheet metal indoor Field wiring LED A (outdoor) (discharge) (condenser) Outdoor Z1C~Z4C Ferrite core LEDA Pilot lamp X1M, X2M Terminal strip...
  • Page 25 • Outdoor Units • R-410A • RX-JV/GV Wiring diagram 7 - 1 Wiring diagram RX71GV Power supply To indoor unit Sheet metal indoor Field wiring LED A (outdoor) (discharge) (condenser) Outdoor Z1C~Z7C Ferrite core LEDA Pilot lamp X1M, X2M Terminal strip...
  • Page 26: Sound Data

    • Outdoor Units • R-410A • RX-JV/GV Sound data 8 - 1 Sound pressure spectrum RX20JV Cooling Heating Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz)
  • Page 27 • Outdoor Units • R-410A • RX-JV/GV Sound data 8 - 1 Sound pressure spectrum RX35JV Cooling Heating Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz)
  • Page 28 • Outdoor Units • R-410A • RX-JV/GV Sound data 8 - 1 Sound pressure spectrum RX60G Cooling Heating Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz)
  • Page 29: Operation Range

    • Outdoor Units • R-410A • RX-JV/GV Operation range RX20-35JV Cooling (-15°C DB) Indoor temp. (°C WB) Indoor temp. (°C DB) 3D058975A The graphs are based on the following conditions. Equivalent piping length Level difference RX50-60G RX71GV Heating Cooling (-15°C DB) Indoor temp.
  • Page 30 The present publication is drawn up by way of information only and does not constitute an offer binding conditioning equipment, compressors and refrigerants upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its has led to its close involvement in environmental issues.