Daikin Emura RXJ20A5V1B Service Manual page 74

Split 3 r32
Hide thumbs Also See for Emura RXJ20A5V1B:
Table of Contents

Advertisement

4
|
Components
Service manual
74
A
a
c
A Class 20~35 unit
a Nut
b Compressor
c Damper
A
a
c
A Class 42+50 unit
a Nut
b Compressor
c Damper
INFORMATION
The compressor dampers may look different.
7 Supply nitrogen to the refrigerant circuit. The nitrogen pressure MUST NOT
exceed 0.02 MPa.
8 Wrap a wet rag around the compressor pipes and any other components near
the compressor and solder the compressor pipes to the refrigerant pipes.
b
b
c
a
c
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32