To install the DC fan motor assembly
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
2 Disconnect the DC fan motor connector from the main PCB.
d
e
d
a DC fan motor connector
b DC fan motor harness
c Switch box
d Screw
e DC fan motor assy
3 Detach the DC fan motor harness from the switch box.
4 Slightly bend the harness retainers (if applicable) to detach the DC fan motor
harness.
5 Remove the 4 screws that fix the DC fan motor assembly.
6 Remove the DC fan motor assembly from the unit.
7 To install the DC fan motor assembly, see
1 Install the DC fan motor assembly in the correct location.
2 Fix the DC fan motor assembly to the unit by tightening the screws.
d
e
d
a DC fan motor connector
b DC fan motor harness
c Switch box
d Screw
e DC fan motor assy
3 If applicable: Route the DC fan motor harness through the harness retainers
and bend the harness retainers to attach the DC fan motor harness.
a
c
b
"Repair
a
c
b
4
Components
|
4
procedures" [
 136].