Piping Diagram: Outdoor Unit - Daikin Emura RXJ20A5V1B Service Manual

Split 3 r32
Hide thumbs Also See for Emura RXJ20A5V1B:
Table of Contents

Advertisement

7.3.2 Piping diagram: Outdoor unit

·7.0· CuT
·7.0· CuT
·9.5· CuT
·9.5· CuT
·7.9· CuT
h
R3T
·7.9· CuT
a Field piping (liquid: Ø6.4 mm flare connection)
b Field piping (gas: Ø9.5 mm flare connection)
c Liquid stop valve
d Gas stop valve
e Muffler with filter
f Heat exchanger
g Accumulator
h Muffler
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08
RXJ20~35A
INFORMATION
The diagrams shown in this manual may be incorrect due to changes/updates to the
unit. Correct diagrams are supplied with the unit and can also be found in the
technical data book.
f
R2T
·4.8· CuT
·4.8· CuT
M
M1F
·9.5· CuT
Y1S
·9.5· CuT
g
M1C
R1T
Y1E
e
e
·6.4· CuT ·6.4· CuT
e
·6.4· CuT
c
h
h
·9.5· CuT
·9.5· CuT
M1C Compressor
M1F Fan
R1T Thermistor (outdoor air)
R2T Thermistor (heat exchanger)
R3T Thermistor (discharge pipe)
Y1E Electronic expansion valve
Y1S 4-way valve (ON: heating)
Refrigerant flow: cooling
Refrigerant flow: heating
7
Technical data
|
·Ø.4.0 x ID.2.0· CuT
a
·6.4· CuT
d
b
·9.5· CuT
Service manual
209

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents