To install the swing flap motor gearcase assembly
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08
a Screw
b Swing flap motor gearcase assembly
8 Disconnect the swing raster motor rod from the swing raster shaft.
9 Remove the swing flap motor gear case assembly from the indoor unit.
10 Disconnect the wiring harness from the secondary swing flap motor and from
the swing raster motor.
11 To install the swing flap motor gearcase assembly, see
procedures" [
4
 166].
1 Connect the wiring harness to the secondary swing flap motor and to the
swing raster motor.
2 Install the swing flap motor gearcase assembly on the correct location on the
indoor unit while guiding the rod inside the swing raster compartment.
3 Install the 3 screws, but do NOT yet tighten them.
a
a Screw
b Swing flap motor gearcase assembly
4 Connect the swing raster motor rod to the swing raster shaft using soft tools.
b
c
a Fan guard
b Swing raster motor rod
c Swing raster
5 Tighten the 3 screws to fix the swing flap motor assembly.
6 Connect the drain hose to the indoor unit.
7 Install the drain hose fixation bracket. Install and tighten the screw.
8 Install the right side fan guard on the indoor unit (by clicking it on).
9 Install the secondary swing flap in the indoor unit (by clicking it on).
b
a
a
4
Components
|
"Repair
a
Service manual
167