RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08
U Wire terminal U
V Wire terminal V
W Wire terminal W
4 Remove the compressor thermal protector, see
thermal
protector" [
5 Remove the putty from the compressor accumulator. Keep for reuse.
6 Supply nitrogen to the refrigerant circuit. The nitrogen pressure MUST NOT
exceed 0.02 MPa.
7 Wrap a wet rag around the components near the compressor pipes. Heat the
brazing points of the compressor pipes using an oxygen acetylene torch and
remove the refrigerant pipes from the compressor pipes using pliers.
A
a
A Class 20~35 unit
a Compressor pipe
V
U
W
4
79].
4
Components
|
"To remove the compressor
a
Service manual