4
|
Components
Service manual
80
A
A Class 42+50 unit
a Compressor wire terminals cover
2 Remove the compressor thermal protector with bracket from the compressor
housing.
b
a
a Compressor thermal protector
b Faston connector
c Bracket
3 Disconnect the Faston connectors from the compressor thermal protector.
4 Separate the compressor thermal protector and the compressor thermal
protector bracket.
a Compressor thermal protector
b Compressor thermal protector bracket
a
c
a
b
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08