3
|
Troubleshooting

3.4 To perform a test run

3.4.1 To perform a test run using the wireless remote control

Service manual
18
INFORMATION
If the unit runs into an error during commissioning, see the service manual for the
detailed troubleshooting guidelines.
Prerequisite: Power supply MUST be in the specified range.
Prerequisite: Test run may be performed in cooling or heating mode.
Prerequisite: Test run should be performed in accordance with the operation
manual of the indoor unit to make sure that all functions and parts are working
properly.
1 In cooling mode, select the lowest programmable temperature. In heating
mode, select the highest programmable temperature. Test run can be
disabled if necessary.
2 When the test run is finished, set the temperature to a normal level. In cooling
mode: 26~28°C, in heating mode: 20~24°C.
3 The system stops operating 3 minutes after the unit is turned OFF.
INFORMATION
Even if the unit is turned OFF, it consumes electricity.
When the power turns back on after a power break, the previously selected
mode will be resumed.
1 Press
to enter main menu and navigate to "Wireless remote control
settings menu" by
2 Navigate to "Software and version" screen by
3 Keep pressed
for at least 5 seconds to enter "Self-diagnosis menu".
Wireless remote control setting menu
4 In the "Self-diagnosis menu", navigate to "Test run menu" by
5 Press
to enter the menu.
6 Change status to ON by
7 Press
to confirm the selection.
Result: The indoor unit enter test run mode, during which normal operation is
not possible.