4
|
Components
To remove the DC fan motor assembly
To install the DC fan motor assembly
Service manual
142
INFORMATION
Use a pulley remover if the propeller cannot be removed manually.
4 To install the propeller fan blade assembly, see
1 Remove the propeller fan blade assembly from the DC fan motor assembly,
see
"Repair
procedures" [
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
2 Disconnect the DC fan motor connector from the main PCB.
3 Cut the tie strap.
e
f
a Tie strap
b DC fan motor harness
c Switch box
d Fan motor bracket
e Screw
f DC man motor assy
4 Detach the DC fan motor harness from the switch box.
5 Slightly bend the harness retainers (at the back of the fan motor bracket) to
detach the DC fan motor harness.
6 Remove the 4 screws that fix the DC fan motor assembly.
7 Remove the DC fan motor assembly from the unit.
8 To install the DC fan motor assembly, see
1 Install the DC fan motor assembly in the correct location.
2 Fix the DC fan motor assembly to the unit by tightening the screws.
4
 141].
c
d
e
a
"Repair
4
"Repair
procedures" [
 141].
b
4
procedures" [
 141].
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08

Hide quick links:

Advertisement

Table of Contents