4
|
Components
To remove the electrical wiring box cover
Service manual
152
a Hook
Prerequisite: If working space is limited.
7 Slide the flat screwdriver in the direction of triangle on the rib into the half-
moon shaped dent on the grille.
a Triangle symbol
8 Slightly press down the front grille and insert the screwdriver in slot next to
the hooks.
9 Pull the front grille up using the flat screwdriver and pull towards the front
side.
a Slot
b Half-moon shaped dent
TO OPEN THE SERVICE COVER
1 Remove 1 screw from the service cover.
2 Pull out the service cover horizontally away from the unit.
a Service cover
b Service cover screw