Secondary Swing Flap Motor - Daikin FTXA20A Service Manual

Split stylish r32
Table of Contents

Advertisement

2
|
Components
To install the swing flap motor gearcase assembly

2.17.2 Secondary swing flap motor

Checking procedures
To perform an electrical check of the swing flap motor
Service manual
140
3 Disconnect the swing flap motor harness from the swing flap motor.
4 To install the swing flap motor gearcase assembly, see
4
procedures" [
 139].
1 Connect the swing flap motor harness to the swing flap motor connector.
2 Install the swing flap motor gearcase assembly on the indoor unit and tighten
using the 2 screws.
a Screw
b Swing flap motor gearcase assembly
3 Install the main swing flap in the indoor unit (by clicking it on).
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Disconnect the swing flap motor connector from the indoor unit main PCB.
2 Measure the resistance between the following pins of the motor connector.
Result: The measurements MUST be as shown in the table below.
Pins
6-7
6-8
6-9
6-10
a
a
b
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"2.14 Plate
work" [
Measured resistance (Ω)
232.5~267.5
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
"Repair
4
 120].
RXA20~35A(9) + RXA42+50B