To install the indoor unit main PCB
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04B – 2022.08
b
b
a Indoor unit main PCB
b PCB support
3 Remove the indoor unit main PCB from the indoor unit.
4 To install the indoor unit main PCB, see
1 Install the indoor unit main PCB in the correct location on the PCB supports.
b
b
a Indoor unit main PCB
b PCB support
2 Connect all connectors to the indoor unit main PCB.
INFORMATION
Use the wiring diagram and connection diagram for correct installation of the
connectors, see
a
"4.9.2 Repair
a
"7.2 Wiring
diagram" [
4
 199].
4
Components
|
b
b
4
procedures" [
 106].