Repair Procedures - Daikin Emura RXJ20A5V1B Service Manual

Split 3 r32
Hide thumbs Also See for Emura RXJ20A5V1B:
Table of Contents

Advertisement

4
|
Components

4.5.2 Repair procedures

To remove the front panel motor gearcase assembly
To install the front panel motor gearcase assembly
Service manual
92
INFORMATION
To replace the motor, the complete gearcase assembly MUST be replaced.
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 On the front grille (removed from the indoor unit), remove the connector
from the connector holder.
b
a Connector
b Connector holder
c Screw (front panel motor gearcase assy)
d Front panel motor gearcase assy
2 Remove the 2 screws and remove the front panel motor gearcase assembly
from the front grille and lever.
3 To install the front panel motor gearcase assembly, see
4
procedures" [
 92].
1 Install the front panel motor gearcase assembly in the correct location on the
front grille and on the lever.
"4.14 Plate
d
c
a
c
4
work" [
 144].
"4.5.2  Repair
RXJ20~50A + FTXJ-A(W)(S)(B)