9. Move to menu Reader options.
10. Select the required Card format.
11. Press [ENTER] until the display indicates menu Hardware options.
12. Press 0 [ENTER] [ENTER] to leave menu 2-Door / Lift options
13. Move to menu 4-Display card and badge a number of cards to verify the
cards are being read, the card number is known.
14. Proceed with the basic set-up.

Basic set-up

1. Set the DGP address for the four-door/four-lift DGP (1 to 12 available).
2. Check if the RAM memory in ATS125x/1260 and the Advisor Master control
panel is the same.
3. Set addresses of RAS's (readers or DGP's connected to the local databus of
the four-door/four-lift DGP.
4. In the Advisor Master control panel, installer programming (menu 19):
- In the Advisor Master control panel menu 4. DGP, activate polling for the
four-door/four-lift DGP and set the DGP type.
- Check and note in the Advisor Master control panel, menu 7. system options
the settings for Dual zone and the Number of prefix digits.
- In menu 13. Timezones, program timezones required for access control
functions (Request To Exit, Override timezone and Door groups)
- In menu 2, Area database, determine which area/s will inhibit Request to
Exit or will inhibit access through a door when the area/s are armed.
5. Go to menu 28, To remote devices. Select type 1 (DGP) and press [ENTER].
Enter the DGP address and press [ENTER]. You now are in the four-
door/four-lift programming menu.
6. Go to menu 1-DGP options.
Set or select the following options:
- Number of Output controllers.
- Enter the required Batch Number (range 1 to 40). If card numbers or system
codes are unknown, then first see Finding system codes for cards (page 5).
- Alarm Code Prefix Digits (same as in control panel).
- Enter RASes to be polled connected to the local databus.
- Enter LCD RAS connected to the local databus.
- Enter RASes with RTE enabled that are connected to the local databus.
- Enter DGP to be polled connected to the local databus.
- Set Dual zone to the same setting as used in the control panel.
- Enter the Card to PIN time (only if Card & PIN required).
- Enter Two cards time (only if required).
- Enter Multiple Badge time (only if alarm control is required).