Basic Installation - Interlogix ZEROWIRE ZW-6404 Installation Manual

Wireless security & home automation
Table of Contents

Advertisement

Installation Using a Keypad

Basic Installation

It is possible to quickly install and test zones using only the ZeroWire keypad, the voice
guide will walk you through each option that requires programming.
Additional zone settings can be accessed via the ZeroWire Web Server, UltraSync + app,
or DLX900.
The keypad will be locked in screensaver mode when unused for a set time. A valid PIN is
required to unlock the ZeroWire and access the ZeroWire system. Users can set PIN
codes between 4 and 8 digits in length.
Please note that the PIN code should be entered twice to be validated.
When an incorrect PIN is entered 3 times the keypad is locked for 60 seconds and the
voice will say "Access denied". During this time the keypad will not be operational and PIN
codes cannot be entered.
After the 60 seconds expires, if the first PIN attempt is incorrect, the 60 second time will
start again. If the PIN code is valid, then the counter will reset and further 3 attempts can
be accepted.
Unpacking Detectors
These instructions are for general information only. Please refer to the manual included
with each detector for further details.
1. Remove the detector from packaging.
2. Remove a battery cover of the detector.
3. Install batteries taking care to insert them correctly. Batteries inserted with reverse
polarity may damage the detector.
Installation Suggestions
Wireless detectors feature low power transmission to maximize battery life. This means
you should place the ZeroWire in a central location and install detectors as close to the
ZeroWire as possible.
Signals from each detector will reduce in strength as they pass through different
building materials with brick and concrete absorbing more of the signal.
Keep detectors away from household appliances and metal surfaces (e.g. refrigerator,
TV, washing machine, garage door). Metal surfaces will reflect the signal away.
If you have a double-storey property, it is suggested the ZeroWire unit be installed on
the highest level for the best signal strength.
ZeroWire installed below ground level (e.g. basement) may have reduced range.
Motion/Passive Infra-Red (PIR) detectors should be installed to look over the area you
want to protect. The path of an intruder should walk across the front of the PIR. A PIR
ZeroWire Installation Manual
49