Shunting
XX, No Shunting
*-Change,Opt:
This record configures the door shunting options. Shunting is a procedure that
inhibits an open door, which could cause an alarm, for a set time.
0: No shunting. The door is not shunted.
1: Zone Shunting. The door is shunted. Generates a standard alarm, based
on the zone type settings, if left open longer than the programmed shunt time.
2: Zone Shunting & DOTL. The door is shunted and generates a DOTL (Door
Open Too Long) alarm if it is left open longer than the programmed shunt
time. Enables Forced Door and DOTL to be reported on separate zone
numbers (as recorded in "Hardware Options").
3: Auto Shunting & DOTL. If the area assigned to the door is disarmed,
shunting of the door commences when the door zone is active (no code or
card required). A DOTL (Door Open Too Long) alarm is generated if it is left
open longer than the programmed shunt time. Forced Door and DOTL are
reported on separate zone numbers as above.
Shunt time
XX,Shunt Time 60 Seconds
*-Min, Time:
Program the amount of time that the door may be opened for without causing an
alarm (shunted). This allows time for a user to pass through the door and shut it
again.
See also "Shunt zone numbers" on page 34.
Extended shunt time
XX,Extended Shunt Time 90 Seconds
*-Min, Time:
Program the amount of time for the door to be shunted when a user, with the
"EXTENDED ACCESS" flag enabled, presents a valid card or PIN at the door
reader.
Shunt warning time
XX,Shunt Warning Time 15 Seconds
*-Min, Time:
Program the amount of time for an output to activate, to sound a warning device,
before the Shunt Time or Extended Shunt Time expires.
See also "Warning output number" on page 34.
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
17