Interlogix ATS125 Series Programming Manual page 58

Fourdoor/four-lift dgp
Hide thumbs Also See for ATS125 Series:
Table of Contents

Advertisement

Macro event flags
List of predefined event flags
Door related events
Event
Door open
Door unlocked
Door lock
Door override
Door override inhibit
[1]
Door disabled
Door enabled
Door reader disabled
[2]
Door reader enabled
Door two card inside
[3]
Door two card
outside
[3]
Door low security
inside
[3]
Door low security
outside
[3]
Door anti-passback
[3]
Door shunting
Door shunt warning
Door area armed
Door interlock
52
Description
Door open command is active (to
unlock / start shunt)
Unlock output is active to unlock
the door
Unlock output is de-activated to
lock the door
The low security timezone
assigned to the door is valid
The low security timezone is
inhibited
Door is disabled completely (from
keypad or computer)
Door is enabled
Reader is disabled
Reader is enabled
Two Card access is required at
the "IN" reader
Two Card access is required at
the "OUT" reader
Card and PIN required to access
at the "IN" reader
Card and PIN required to access
at the "OUT" reader
Anti-Passback is active
Shunt timer is running
Shunt warning timer is running
Area assigned to door is armed
(As macro output this event
disables a door when "access
denied when Armed" is set to
YES)
Interlock zone(s) are active
Input (I),
Output (O),
Both (I/O)
I / O
I / O
O
I / O
I / O
I / O
O
I / O
O
I / O
I / O
I / O
I / O
I / O
I / O
I
I / O
I / O
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
Door
1
2
3
4
1
2
3
4
9
10
11
12
17
18
19
20
25
26
27
28
33
34
35
36
41
42
43
44
49
50
51
52
57
58
59
60
65
66
67
68
73
74
75
76
81
82
83
84
89
90
91
92
97
98
99
100
105
106
107
108
113
114
115
116
121
122
123
124
129
130
131
132
137
138
139
140

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ats1260

Table of Contents