6 Lift Options
XX, Menu
These options are only available for the ATS1260 four-lift DGP.
Starting floor of lift
XX, First Floor 1
*-Dis, Floor:
This record sets up the starting floor number the lift will control. For example, if
this lift was controlling floors 1 to 8, then this "Starting Floor" option needs to
be 1. Also, see the next option, "Last Floor'".
Last floor of lift
XX,Last Floor 64
*-Dis, Floor:
This record sets up the last floor number the lift will control. For example, if this
lift was controlling floors 1 to 8, then this "Last Floor" option needs to be 8. Also,
see the previous option, "Starting Floor".
Starting physical relay
XX, First Physical Relay 1
*-Dis, 0/p:
This record configures the physical starting output number, on ATS1260, for the
range of outputs that the lift uses to disarm and arm floors. For example, if this lift
was controlling floors 1 to 8 and the outputs, used to disarm those floors, were
outputs 21 to 28 on the ATS1260, then enter 21 here. When this value is
entered, the ATS1260 interprets this as follows:
Physical Output is 21 ("physical" meaning the available output on board the
ATS1260).
Starting Floor is 1 and Last Floor 8, meaning 8 floors.
Therefore, the Physical Output range is 21 to 28.
So, outputs 21 to 28 on this ATS1260 are used for this lift to arm and disarm
floors.
The ATS1260 automatically calculates the last output number required to arm
and disarm the floors it controls. The floor range in the options 'Starting Floor'
and 'Last Floor' determines this.