Interlogix ATS125 Series Programming Manual page 28

Fourdoor/four-lift dgp
Hide thumbs Also See for ATS125 Series:
Table of Contents

Advertisement

IN reader Two Cards function
XX, NO - In Reader Two Cards
*-Change
Controls if two user cards or PINs are required to gain access. Separate
programming records are provided for the IN and OUT reader for each door.
Yes: Two different users need to present their card and/or PIN within the Two
cards time for the door to unlock.
No: Only one user is needed to present a card and/or PIN.
OUT reader Two Cards function
XX, NO - Out Reader Two Cards
*-Change
Controls if two user cards or PINs are required to gain access. Separate
programming records are provided for the IN and OUT reader for each door.
Yes: Two different users need to present their card and/or PIN within the Two
cards time for the door to unlock.
No: Only one user is needed to present a card and/or PIN.
Required HSU Number
XX, Required HSU Number 0
Number:
This value defines how many High Security Users must be present in the region
assigned to the selected door.
Prewarning time
XX, Prewarning time 0 sec
Time:
This value defines time (in seconds) for the prewarning timer to run. When there
are too few HSUs in high security region, a prewarning timer starts, and when it
expires, an alarm is raised and the alarm output activates.
OUT reader, no TZ required
XX, NO - OUT reader, no TZ required
*-Change
This option extends the exit access for the selected reader.
Yes: The user has an access to the door from the OUT reader side even if his
timezone has already expired. But he must have assigned any TZ for the door
in his doorgroup - users without TZ do not have an access to the door.
22
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide