No: No reporting unless an alarm occurs (depends on zone type).
Note:
This is only a reporting function.
Report DOTL
XX, NO - Report DOTL
*-Change
Report when the Door is open too long.
Yes: Report to the printer and to Titan when the zone assigned to the door is
in the DOTL state — for example, still open after the shunt timer expires.
No: No reporting unless an alarm occurs (depends on zone type).
Note:
This is only a reporting function.
Reader LED options
XX, LED1 On When Locked
*-Change:
This record specifies the status that the reader LEDs will indicate (not applicable
for PIN readers).
0: LED 1 On When Locked. LED 1 is on, when the door is locked.
1: LED 1 On When Unlocked. LED 1 is on, when the door is unlocked.
2: LED 1 On When Areas Armed. LED 1 indicates if the area assigned to the
door is armed (if more than one area is assigned, all areas assigned to the
door must be armed before LED changes state).
3: LED 1 Off When Areas Armed. LED 1 indicates if the area assigned to the
door is disarmed (if more than one area is assigned, all areas assigned to the
door must be disarmed before LED changes state.)
4: Two LED Arm/Disarm. Readers with dual LED control lines connected
indicate the area disarmed and armed with different LED colours.
5: Two LED Valid/Void. Readers with dual LED control lines connected
indicate User Valid or Void using different LED colours.
6: LEDs Disabled. No LED control.
Note:
On readers with dual LED control lines, LED 2 may also be programmed to
indicate other condition(s) using ATS125x macro logic programming.
See also "Areas assigned to door" on page 35.