See also "Zone holds door unlocked" on page 28.
Region count limit
XX,Region Count Limit Disabled
*-Dis, No:
When the number of users reaches this limit (set by the value entered in this
option – range, 0 to 65,535), ATS125x sets an internal flag (Region count limit)
that can be used in Door Macro Logic. You may activate events when a certain
number of users are in a region. The Advisor Master system can have up to
256 regions, numbered 0 to 255.
Examples:
Activate a sign when a car park is full.
Arm area(s) when the last person has left the region or disarm area(s) when
the first person enters the region.
See also "IN reader region" on page 20.
Map DGP relays
XX,Yes - Map DGP relays
*-Change
Defines whether ATS125x/1260 door unlock outputs can be controlled as
standard outputs.
Yes: Door unlock outputs can be controlled by the control panel as its
outputs.
No: Door unlock outputs can only be activated by DGP when using door
unlock user menu, or upon presenting a valid card.
Map panel RAS LED's status
XX,Yes - Map panel RAS LEDs status
*-Change
When this option is set to Yes, LEDs in RASes (ATS110x and ATS111x)
connected to the four-door/four-lift DGP will represent the same status as LEDs
in RASes connected directly to the panel.
Screensaver
XX,Yes - Screensaver
*-Change
When this option is set to Yes, RASes ATS110x and ATS111x connected to the
four-door/four-lift DGP have screensaver option. In the screensaver mode, the
status of RAS LEDs is not shown. Only green LED is active (blue in case of
ATS1190).