Interlogix ATS125 Series Programming Manual page 9

Fourdoor/four-lift dgp
Hide thumbs Also See for ATS125 Series:
Table of Contents

Advertisement

- Enter Re-lock delay time.
- Enter Region count limit (only if anti-passback is used).
7. Go to menu 2-Door / Lift options.
8. Select the door to program. Only doors available on the selected DGP can be
entered.
9. Now the first menu will be visible, Access options.
Set or select the following options:
- Select the door to program
- Unlock time
- Extended unlock time (if required)
- Shunting option (if required)
- Shunt time (if required)
- Extended shunt time (if required)
- Shunt warning time (if required)
- Shunt until door has closed
- Cancel shunt time after door closed
- Low security timezone (if required)
- IN / OUT reader requires card and PIN
- IN / OUT reader inhibit PIN if timezone
- IN / OUT reader inhibit region 0 user
- Anti-passback option (if required)
- IN / OUT reader region (if required)
- IN / OUT reader Two Cards function
10. Move to menu Request To Exit options (only if required)
Set or select the following options:
- Request To Exit Timezone
- IN or OUT RTE disabled if area is armed
- Request To Exit control
- Request To Exit reporting
11. Move to menu Reader options
Set or select the following options:
- Card format
- Zone holds door unlocked
- Door unlocked until door open
- Unlocked timezone (if required)
- Unlocked timezone after entry
- Report when door closed and locked
- Report open/unlocked as unlocked
- Report door open / close
- Report forced door
- Report DOTL
- Reader LED options
- Pulsed lock and unlock
- Disable Duress functionality
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide