Alarm, error, and system messages
17.6 PLC and NC variables
17.6
PLC and NC variables
17.6.1
Displaying and editing PLC and NC variables
Changes can only be made to the NC/PLC variables with the appropriate password.
Incorrect parameterization
Changes in the states of NC/PLC variables have a considerable influence on the machine.
Incorrect configuration of the parameters can endanger life and cause damage to the machine.
In the "NC/PLC Variables" window, enter the NC system variables and PLC variables that you want
to monitor or change in the list:
• Variable
Address for NC/PLC variable.
Incorrect variables have a red background and are displayed with a # character in the value
column.
• Comment
Any comment on the variable.
The columns can be displayed and hidden.
• Format
Specify the format in which the variable is to be displayed.
The format can be specified (e.g. floating point).
• Value
Displays the actual value of the NC/PLC variables.
PLC variables
Inputs
Outputs
Bit memory
Times
Counters
Data
418
WARNING
•
Input bit (Ex), input byte (EBx), input word (EWx), input double word (EDx)
•
Input bit (Ix), input byte (IBx), input word (IWx), input double word (IDx)
•
Output bit (Ax), output byte (ABx), output word (AWx), output double
word (ADx)
•
Output bit (Qx), output byte (QBx), output word (QWx), output double
word (QDx)
Memory bit (Mx), memory byte (MBx), memory word (MWx), memory double
word (MDx)
Time (Tx)
•
Counter (Cx)
•
Counter (Cx)
•
Data block (DBx): Data bit (DBXx), data byte (DBBx), data word (DBWx),
data double word (DBDx)
•
Data block (VBx): Data bit (VBXx), data byte (VBBx), data word (VBWx),
data double word (VBDx)
Operating Manual, 07/2021, 6FC5398-6AP40-6BA4
Universal