Tool Mode
Note Never turn OFF the power when processing messages for saving
Saving Data to a Personal Computer (V530-C300E “ Personal Computer)
Procedure
1,2,3...
or loading operations are displayed. Data may be lost, and the
V530-C300E may not operate properly the next time it is started.
1.
Connect the COM1 port on the computer and the V530-C300E
using an RS-232 cable.
2.
Make the V530-C300E communication settings.
The default communication settings are as shown in the following
table. These settings can be normally used.
Item
Baud rate
Data length
Parity bits
Stop bits
Footer
3.
Start the Hyper Terminal program on the computer and make the
following communication settings.
The same communication settings must be used on both the
V530-C300E and the modem on the computer.
Item
Baud rate (B)
Data length (D)
Parity bits
Stop bits
Flow control
4.
Save data from the V530-C300E.
Setting
38400 (bps)
8 (bit)
None
1 (bit)
CR
Setting
38400 (bps)
8 (bit)
None
1 (bit)
None (XMODEM protocol is used.)
Section 5-4
115