SET (Setting) Mode
Procedure
1,2,3...
98
1.
Select 2. Image Analysis and press the ENT Key.
0. Image Adjust
1. Read DM (Normal)
2. Image Analysis
Analyse input image.
2.
Select either Line Bright X or Line Bright Y as required and
press the ENT Key.
3.
Select the gray edge level for black and white judgment.
(1 to 255)
Press the ENT Key to change the cursor to fill one digit or charac-
ter. Use the Left/Right Keys to change line and use the Up/Down
Keys to change the gray edge level.
4.
Select Register. The Line Bright screen will be displayed.
5.
Move the cross cursor with the Up/Down/Left/Right Keys and
press the ENT Key when the cursor is at the beginning point of
the required line. Press the SHIFT Key together with the above
keys to move the cursor faster.
6.
Move the cross cursor with the Up/Down/Left/Right Keys and
press the ENT Key when the cursor is at the end point of the re-
quired line.
Display Pixel Value
Image Magnifier
Measure Length
Hardware Check
Contrast (Line Bright)
Contrast (Region)
Gray Edge Value [32]
Register
Cancel