Configuring the Core Interface
Figure 5-4
Temperature panel
Table 5-3
Temperature configuration parameters
Parameter
Description
Damping Period
The number of seconds over which the reported temperature
value will change to reflect 63% of the change in the actual
process. See Section 5.5.2.
Calibration Slope
The slope value used to adjust the temperature process
variable.
Calibration Offset
The offset value used to adjust the temperature process
variable.
External
• Disabled: Temperature data from the Micro Motion sensor will
Temperature
be used.
• Enabled: Temperature data from a different temperature
device will be used. If Enabled is specified, a Source field is
displayed. Use the Select TLP dialog box to specify the
temperature source. The Value field displays the current
temperature value from the specified source.
42
Comments
Default: 4.8 seconds
Default: 1.0
Default: 0.0
Applies to all Model 3711
calculations that require a
temperature value.
®
Micro Motion
Model 3711 Gas Flow Computers