Maintenance and Troubleshooting
Table 15-1
Status alarms and remedies continued
Alarm
code
Message
A005
Input Overrange
A008
Density Overrange
A010
Calibration Failure
A016
Line Temp Out-of-range
A017
Meter Temp
Out-of-Range
A020
Cal Factor Unentered
A021
Incorrect Sensor Type
A022
Configuration Corrupt
A023
Totals Corrupt
A024
CP Program Corrupt
A025
Boot Sector Fault
A102
Drive Overrange
A104
Calibration in Progress
A105
Slug Flow
A107
Power Reset
NA
Sensor Not Vibrating
NA
Low Amplitude
NA
Clip Flag
Configuration and Use Manual
Possible remedy
Check the test points. See Section 15.16.
Check the sensor pins. See Section 15.18.
Verify process.
Verify calibration factors in Model 3711 configuration. See Section 15.13.
Re-zero the Model 3711. See Section 5.6.
Check the test points. See Section 15.16.
Check the sensor pins. See Section 15.18.
Verify process. Check for air in the flow tubes, tubes not filled, foreign material
in tubes, or coating in tubes.
Verify Model 3711 characterization. See Section 15.13.
Perform density calibration. See Section B.4.
If alarm appears during a zero procedure, ensure that there is no flow through
the sensor, then retry.
Cycle power to the meter, then retry.
Check the test points. See Section 15.16.
Check the sensor pins. See Section 15.18.
Check wiring to sensor. See Section 15.15.2.
Contact Micro Motion. See Section 1.8.
Check the test points. See Section 15.16.
Check the sensor pins. See Section 15.18.
Contact Micro Motion. See Section 1.8.
Check the characterization. Specifically, verify the FCF value. See
Section 15.13.
Check the characterization. Specifically, verify the K1 value. See Section 15.13.
Cycle power to the meter.
The Model 3711 might need service. Contact Micro Motion. See Section 1.8.
Cycle power to the meter.
The Model 3711 might need service. Contact Micro Motion. See Section 1.8.
Cycle power to the meter.
The Model 3711 might need service. Contact Micro Motion. See Section 1.8.
Cycle power to the meter.
The Model 3711 might need service. Contact Micro Motion. See Section 1.8.
Excessive drive gain. See Section 15.16.2.
Check the sensor pins. See Section 15.18.
Allow the meter to complete calibration.
See Section 15.12.
No action required.
Contact Micro Motion. See Section 1.8.
Contact Micro Motion. See Section 1.8.
Contact Micro Motion. See Section 1.8.
175