Emerson Micro Motion 3711 Configuration And Use Manual page 214

Gas flow computers
Table of Contents

Advertisement

Points and the TLP System
Table C-2
UDP 37 parameters continued
Read/
Parameter
Write
5
R/O
6
R/O
7
R/O
8
R/O
9
R/O
10
R/O
11
R/O
12
R/O
13
R/O
14
R/O
15
R/O
16
R/O
17
R/O
18
R/O
19
R/O
20
R/O
21
R/O
22
R/O
23
R/O
24
R/O
25
R/O
26
R/O
27
R/O
28
R/O
29
R/O
30
R/O
31
R/O
32
R/O
33
R/O
34
R/O
35
R/O
36
R/O
37
R/O
38
R/O
39
R/O
40
R/O
41
R/O
42
R/O
43
R/O
206
Data
type
Length
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
UINT16
2
UINT8
1
FL
4
Default
Range
value
0 – 65535
247
1 – 16
FL (7)
NA
0.0
0 – 65535
249
1 – 16
FL (7)
NA
0.0
0 – 65535
251
1 – 16
FL (7)
NA
0.0
0 – 65535
2
1 – 16
BIN (8)
0 , 1
1.0
0 – 65535
71
1 – 16
BIN (8)
0 , 1
0.0
0 – 65535
79
1 – 16
BIN (8)
0 , 1
0.0
0 – 65535
81
1 – 16
BIN (8)
0 , 1
0.0
0 – 65535
82
1 – 16
BIN (8)
0 , 1
0.0
0 – 65535
86
1 – 16
BIN (8)
0 , 1
0.0
0 – 65535
17
1 – 16
UINT16 (4)
NA
0.0
0 – 65535
39
1 – 16
UINT16 (4)
NA
82.0
0 – 65535
40
1 – 16
UNIT16 (4)
NA
94.0
0 – 65535
41
1 – 16
UINT16 (4)
NA
33.0
Micro Motion
Description
Live Data Register 2 (Mass Rate)
Live Data Register 2 Data Type
Live Data Register 2 Value
Live Data Reg 3 (Sensor Density)
Live Data Register 3 Data Type
Live Data Register 3 Value
Live Data Register 4 (Sensor
Temperature)
Live Data Register 4 Data Type
Live Data Register 4 Value
Setup Reg 1 (Stop Totalizers)
Setup Register 1 Data Type
Setup Data Register 1 Value
Setup Reg 2 (Disable Volume Calcs)
Setup Register 2 Data Type
Setup Data Register 2 Value
Setup Reg 3 (Disable Copper RTD)
Setup Register 3 Data Type
Setup Data Register 3 Value
Setup Reg 4 (Disable Cryogenic Comp)
Setup Register 4 Data Type
Setup Data Register 4 Value
Setup Reg 5 (Disable Pressure Comp)
Setup Register 5 Data Type
Setup Data Register 5 Value
Setup Reg 6 (Disable External Temp)
Setup Register 6 Data Type
Setup Data Register 6 Value
Setup Reg 7 (Flow Direction – Forward)
Setup Register 7 Data Type
Setup Data Register 7 Value
Setup Reg 8 (Mass Rate Units)
Setup Register 8 Data Type
Setup Register 8 Value (lbs/hr)
Setup Reg 9 (Density Units)
Setup Register 9 Data Type
Setup Register 9 Value (lbs/ft3)
Setup Reg 10 (Temperature Units)
Setup Register 10 Data Type
Setup Register 10 Value (Deg F)
®
Model 3711 Gas Flow Computers