Emerson Micro Motion 3711 Configuration And Use Manual page 20

Gas flow computers
Table of Contents

Advertisement

Getting Started
Figure 2-6
3. Specify your I/O type.
If your Model 3711 was ordered without the optional 6-point I/O expansion termination
board, select
If your Model 3711 was ordered with the optional 6-point I/O expansion termination
board, select
4. If you specified
frame to specify how five of the six I/O channels will be used (the sixth channel is always used
as a discrete output). The I/O types specified here must be compatible with the I/O wiring and
switches (see the Model 3711 installation manual for wiring instructions). You can change
these specifications later (see Section 7.3).
5. Specify the number of PID control loops that will be configured for this Model 3711. The
maximum value is 1. This value can be changed later. See Chapter 10 for more information.
6. Specify the maximum number of history points to be used for standard history and extended
history. If you add history points later, you will lose all existing history, so make sure that the
number specified will be sufficient for your Model 3711. See Chapter 8 for more information
about history.
7. Click
8. Specify a name and location to be used for the configuration file, and click
ROCLINK 800 configuration files use the .800 extension.
9. If you want to continue with configuration, open the file when prompted. If you will perform
configuration later, close the file.
12
New Configuration File dialog box
6-point no I/O
6-point with I/O
6-point with I/O
.
Start
.
.
, an External I/O frame is displayed. Use the options in this
Micro Motion
. All
Save
®
Model 3711 Gas Flow Computers