Emerson Micro Motion 3711 Configuration And Use Manual page 224

Gas flow computers
Table of Contents

Advertisement

Soft Points
Figure D-1
2. For each soft point to be configured:
a. Select it from the
b. Enter the tag to be used to identify this soft point in the
maximum of 10 characters.
c. For each data value, you may enter any floating-point value.
Note: You do not need to assign a value to each data value. FSTs and Modbus programs can write
and update data values in the soft point as required. The Soft Point dialog box can be used to display
the current contents of a soft point.
d. Do not enter a value for the integer flag. This field is used as a flag to indicate the validity
of the floating-point data, or as a counter. The value may be under the control of an FST or
other user program.
3. Click
216
Soft Point dialog box
Softpoints
or
.
Apply
OK
dropdown list.
Micro Motion
field. The tag can contain a
Tag
®
Model 3711 Gas Flow Computers