Power synchronization

You can enable the power synchronization feature using the switch on the printer interface board. The default switch
position is OFF.
When you enable power synchronization, the E-85 synchronizes power with the printer's main power off/on status. If the
printer powers off, the E-85 receives signals from the printer through the USB cable connected to the printer interface
board, and automatically starts the shutdown process. If the E-85 receives the startup signals from the printer, the E-85
automatically powers on and begins the startup sequence.
When you enable power synchronization, the E-85 synchronizes power with the printer's main power off/on status. If the
printer powers off, the E-85 receives signals from the printer through the printer interface cables connected to the printer
interface board, and automatically starts the shutdown process. If the E-85 receives the startup signals from the printer, the
E-85 automatically powers on and begins the startup sequence.
Important: After the power synchronization is enabled, make sure to control the E-85 power using the printer.
To enable the power synchronization feature at the E-85
1 Shut down the E-85 (see
2 Set the switch on the printer interface to the ON position.
Important: Do not change the switch position when the E-85 is powered on.
1
Power synchronization switch
Figure 9:
3 Power on the printer.
The E-85 will automatically start up.