Fujitsu PRIMERGY TX1320 M5 Upgrade And Maintenance Manual page 361

Table of Contents

Advertisement

CSS indicator (2)
Status
off
orange on
flashing orange
Global Error indicator (3)
See also
"iRMC-related status signals" on page
Status
off
orange on
flashing orange
HDD/SSD activity indicator (4)
Status
flashing green
TX1320 M5
Description
No critical event detected (CSS component).
Prefailure event detected (CSS component).
For HDDs, see also
page
362.
CSS component failure detected.
Description
No critical event detected (non-CSS component).
Prefailure event detected (non-CSS component).
Non-CSS component failure detected.
Possible causes:
– System is out of the specified temperature range
– Defective sensor
– CPU error
– Error detected by server management software
Description
Data access in progress.
Upgrade and Maintenance Manual
"HDD prefailure detection" on
362.