Tools:
tool-less
Preliminary steps
▶ If the HDD/SSD module to be removed is combined into a RAID array,
proceed as follows:
RAID level
Procedure
RAID 0
RAID 1
Removing an HDD/SSD module from a RAID 1 or RAID 5
array will not result in data loss.
RAID 5
However, the removed drive needs to be replaced
immediately by an HDD/SSD module of the same or larger
capacity.
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
Be sure to back up your data before deleting a RAID array.
For more information, see the "ServerView Suite RAID
Management" user guide.
"Getting access to the component" on page
TX1320 M5
Hard disk drive (HDD) / solid state drive (SSD)
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD/SSD module is defect, all data
are lost!
After replacing the HDD/SSD module, RAID rebuild
will be performed as a background process, see
"Performing a RAID array rebuild" on page