Installing the new system board
▶ If applicable, install the TPM, see
▶ Check the settings on the new system board, see
page
372.
▶ Insert the system board by holding it at a slight angle. Slide the connectors
into the I/O panel, see
▶ Lower the system board carefully into the chassis.
▶ Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion (orange circles in
centering bolts).
▶ Fasten the system board with the eight screws, see
▶ Remove the plastic cover from the CPU socket of the new system board.
▶ Remove the CPU from the defective system board, see
CPU" on page
▶ Confirm that the CPU model number printed on the top of the CPU fits with
the requirements.
▶ Install the CPU on the new system board, see
page
235.
▶ Fit the protective plastic cover onto the socket of the defective system board
which will be sent back to spares.
Returned system boards without this cover probably have to be
scrapped.
▶ Install the heat sink, see
"Installing the performance heat sink" on page
▶ If applicable, install the power distribution board, see
power distribution board" on page
▶ If applicable, install the HDD cage, see
on page
62.
▶ If applicable, install all HDD modules, see
modules" on page
TX1320 M5
Figure
228.
234.
"Installing the standard heat sink" on page 239
152.
Upgrade and Maintenance Manual
System board and components
"Installing the TPM" on page
"Onboard settings" on
"Installing the CPU" on
242.
128.
"Installing the 2.5-inch HDD cage"
"Installing 2.5-inch HDD/SSD
303.
Figure 227
show the
Figure
227.
"Removing the
"Installing the new
or
343