Checking The Usage Status Of The Internal Disk; Enabling The Removal Of An Internal Disk - Fujitsu Oracle M10-1 Service Manual

Hide thumbs Also See for Oracle M10-1:
Table of Contents

Advertisement

# ldm list-io
For maintenance on a PCIe card, retain the output data of the ldm list-io
command, since you will need it later when restoring the original configuration
after maintenance.
5.3.3

Checking the usage status of the internal disk

In the following execution example, the configurations and states of devices in pools
and errors generated from the devices are checked.
1.
Log in to Oracle Solaris on the logical domain.
2.
Execute the zpool status command to check the configurations and operating
conditions of devices.
# zpool status
pool: rpool
state: ONLINE
scan: none requested
config:
errors: No known data errors
pool: testpool
state: ONLINE
scan: none requested
config:
errors: No known data errors
5.4
Enabling the Removal of an Internal
Disk
This section describes the procedure for enabling the removal of an internal disk by
using the hot plug function.
48
Fujitsu M10-1/SPARC M10-1 Service Manual ・ June 2021
NAME
rpool
c1t50000393E802CC86d0
NAME
testpool
c1t500003930821CE9Ad0
c1t500003930820AB02d0
STATE
READ WRITE CKSUM
ONLINE
0
ONLINE
0
STATE
READ WRITE CKSUM
ONLINE
0
ONLINE
0
ONLINE
0
0
0
0
0
0
0
0
0
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oracle sparc m10-1

Table of Contents