Table 4-2     Commands for checking FRU information and resource information
Command
showstatus
showboards
showpcl
showfru
4.2

Troubleshooting

This section explains suspected failure conditions. Use the flow to confirm whether
there is a failure and identify the failure location in the following cases. For details on
the flow for confirming whether there is a failure, see
there is a
When the CHECK LED is on
When an error message is displayed on the console
When an error is displayed as a result of executing a command for checking the
status
When an error is displayed in the error log
4.2.1

Confirming whether there is a failure

This section describes the flow for confirming whether there is a failure. Also apply
this flow to identify failures in the PCI expansion unit.
34
Fujitsu M10-1/SPARC M10-1 Service Manual ・ June 2021
Description
Displays the FRU status. Out of the FRUs in the system
configuration, this command displays information on a faulty or
degraded unit or FRU.
Displays information on a physical system board (PSB). Displays
information on a physical system board that belongs to the
specified physical partition and information on all the physical
system boards that are mounted.
Displays the configuration information for a physical partition
(hardware resource information).
Displays the setting information for a device.