Waiting for FAN#6 to enter install state.
[This operation may take up to 1 minute(s)]
(progress scale reported in seconds)
 
Diagnostic tests for FAN#6 have started.
[This operation may take up to 6 minute(s) 30 second(s)]
(progress scale reported in seconds)
If your XSCF firmware version is earlier than XCP 2220, the underlined part is
displayed as "4 minute(s)."
2.
Confirm that the status is normal ("Normal") after diagnosis, and then enter
"f".
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the replaced FRU.
 
FRU
------------------- --------------
/FAN#6
------------------------------------------------------------------------------
The replacement of FAN#6 has completed normally.[f:finish] : f
When the maintenance menu appears, enter "c" to exit the operation.
3.
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of model which has FRU to be replaced.
 
1. FAN
(Fan Unit)
2. PSU
(Power Supply Unit)
------------------------------------------------------------------------------
Select [1,2|c:cancel] : c
6.3
After Replacing the Motherboard
Unit/PSU Backplane
This section describes the procedure for restoring the system after reinstalling the
motherboard unit or PSU backplane.
78
Fujitsu M10-1/SPARC M10-1 Service Manual ・ June 2021
0.. done
0....
30.....
60.....
Status
Normal
90. done