Returning The Mode Switch To Locked Mode - Fujitsu Oracle M10-1 Service Manual

Hide thumbs Also See for Oracle M10-1:
Table of Contents

Advertisement

Execute the showlogs error command.
3.
Confirm that no new errors are displayed.
XSCF> showlogs error
4.
Execute the showhardconf command.
Confirm that no asterisk (*) is displayed in front of any FRU.
XSCF> showhardconf
SPARC M10-1;
------------------------ Omitted ------------------------
FANU#0 Status:Normal;
FANU#1 Status:Normal;
FANU#2 Status:Normal;
FANU#3 Status:Normal;
FANU#4 Status:Normal;
------------------------ Omitted ------------------------
*1 For an MBU on which the SPARC64 X+ processor is mounted, "Type: B" is displayed. For an MBU on which the
SPARC64 X processor is mounted, "Type: A" is displayed.
*2 If the SPARC64 X+ processor is mounted, "2.800 GHz; Type:0x20", "3.200 GHz; Type:0x20", or "3.700 GHz;
Type:0x20" is displayed.
If the SPARC64 X processor is mounted, "2.800 GHz; Type:0x10" is displayed.
*3 If the SPARC64 X+ (3.7 GHz (8 cores)) processor is mounted, "Core:8" is displayed.
6.8
Returning the Mode Switch to Locked
Mode
1.
Return the mode switch of the operation panel to Locked mode.
For details, see
88
Fujitsu M10-1/SPARC M10-1 Service Manual ・ June 2021
 
+ Serial:2101151008A; Operator_Panel_Switch:Locked;
+ System_Power:Off; System_Phase:Cabinet Power Off;
Partition#0 PPAR_Status:Powered Off;
MBU Status:Normal; Ver:2004h; Serial:USDA-P00007 ;
+ FRU-Part-Number:CA20366-B10X 002AB/LGA-MBU -01 ;
+ Power_Supply_System: Dual ;
+ Memory_Size:32 GB; Type: A ;
CPU#0 Status:Normal; Ver:4142h; Serial: 00010448;
+ Freq:2.800 GHz; Type:0x10;
+ Core:16; Strand:2;
MEM#00A Status:Normal;
+ Code:ce8002M393B5270DH0-YH9 0000-85A8EFD9;
+ Type:01; Size:4 GB;
"2.3.2 Control function of the operation
(*1)
(*2)
(*3)
panel."