Checking The Component Status - Fujitsu ORACLE M10-1 Installation Manual

Hide thumbs Also See for ORACLE M10-1:
Table of Contents

Advertisement

/pci@8000/pci@4/pci@0/pci@0/scsi@0
 
FCode Version 1.00.56, MPT Version 2.00, Firmware Version 17.00.00.00
 
Target a
Unit 0
Disk
SASDeviceName 500003942823ca50
Target b
Unit 0
Encl Serv device
SASAddress 500000e0e04ae2fd
 
<< Displayed execution results of " show-devs">>
/pci@8100/pci@4
/pci@8100/pci@4/pci@0
/pci@8100/pci@4/pci@0/pci@9
/pci@8100/pci@4/pci@0/pci@1
/pci@8100/pci@4/pci@0/pci@0
/pci@8100/pci@4/pci@0/pci@0/network@0,1
/pci@8100/pci@4/pci@0/pci@0/network@0
:
PSB
Test
Fault
---- ------- --------
00-0 Passed
Normal
XSCF>
2.
Check the execution results of "probe-scsi-all" to confirm that all mounted
internal disks are identified.
3.
Check the execution results of "show-devs" to confirm that all mounted PCIe
cards are identified.
4.
Confirm that "Passed" and "Normal" appear for all PSBs in the results from
the initial diagnosis.
If the results display anything other than the above, see
Troubleshooting."
5.8

Checking the Component Status

This section describes the procedure for checking the configuration, status, and
quantities of the mounted field replaceable units (FRUs).
1.
Execute the showhardconf command.
The command displays all the FRUs mounted in the chassis and their status.
However, it does not display the status of I/O-related components such as PCIe
cards and PCI expansion units while the system power is off.
Example: SPARC M10-1 display example
XSCF> showhardconf -M
SPARC M10-1;
+ Serial:21xxxxxxxx; Operator_Panel_Switch:Service;
Fujitsu M10-1/SPARC M10-1 Installation Guide ・ March 2019
86
TOSHIBA
MBF2600RC
SASAddress 500003942823ca52
FUJITSU
PhyNum 14
3706
1172123568 Blocks, 600 GB
NBBEXP
0d32
PhyNum 0
"Appendix A

Advertisement