Replace the Avaya S8800 Server and its components
Replace the Avaya S8800 Server
Reuse of hardware components in replacement servers
When you replace the Avaya S8800 Server, you must reuse the following components:
• DIMMs (4 GB capacity)
• Redundant power supply if used
• PCIe card (dual NIC populated in slot 1 of the server)
• Two hard disk drives
Required equipment and tools
The requirements are as follows:
• Replacement Avaya S8800 Server
The comcode of the replacement Communication Manager S8800 1U Server is
700478522.
• #2 cross-point (Phillips) screwdriver or 3/8 inch flathead screwdriver
• USB keyboard, USB mouse, and monitor
• Electrostatic wrist ground strap and mat
Important:
The replacement server is not shipped with the dual NIC PCI board and redundant power
supply (if used). When you replace the Avaya S8800 Server, you must reuse these
components in the replacement server. If any of these components are not functional in the
failed server, you must order for them as separate items.
Interchanging and busying out the server
About this task
Important:
You must interchange and busy out the server only if you are replacing the Avaya S8800
Server with a duplex configuration. If you are replacing the Avaya S8800 Server with a
simplex configuration, skip this task.
12
Maintaining the Avaya S8800 Server for Avaya Aura
®
Communication Manager
Comments? infodev@avaya.com
July 2012